Three services. One way of working.

We secure the buildings and data centres you already run, cut their energy use and costs, and improve the air in them. Each service looks at different things, and each follows the same four steps: assess, fix, verify, monitor.

We recommend starting with security. Every other change runs through the same controls, so they need to be safe first. Performance and air quality can be added together or on their own.

01 · START HERE

Security

Controls that can't be hacked or changed by the wrong people.

What we look at

  • Every controller, BMS and remote-access path
  • Passwords, user accounts and firmware
  • Internet exposure and network separation

Typical fixes

  • Internet exposure closed, remote access secured
  • Passwords reset, old accounts removed
  • Unsupported devices updated or isolated

What we monitor

  • Changes made by unknown users or at odd hours
  • New accounts, logins and connections
  • Independent sensors that disagree with the controller

02 · LOWER COSTS

Performance

Less energy and lower running costs, with equipment working as designed.

What we look at

  • Schedules against real occupancy
  • Setpoints, overrides and rules that conflict
  • Temperatures, energy use and sensor accuracy
  • Energy prices and tariffs by the hour

Typical fixes

  • Schedules rebuilt around how the building is used
  • Occupancy sensors where schedules can't follow real use
  • Conflicting rules and forgotten overrides removed
  • Faulty sensors replaced or recalibrated
  • Pre-cooling and pre-heating timed for cheaper hours

What we monitor

  • Overrides left in place and rules that fight
  • Sensors drifting, failing or offline
  • Energy use against the baseline
  • Price and grid signals, where your tariff rewards flexibility

03 · HEALTHIER SPACES

Air

Healthy, comfortable air, measured rather than assumed.

What we look at

  • CO2, particles (PM2.5), temperature and humidity by zone
  • Ventilation rates against occupancy
  • Filters and outdoor air settings

Typical fixes

  • Ventilation matched to occupancy
  • Filters and outdoor air dampers corrected
  • Purifiers where ventilation can't keep up

What we monitor

  • Air quality by zone
  • Hours above healthy levels

Data centres

The same services, where cooling, power and computing meet.

Data centres run on the same kinds of controls as any building, with far more at stake. Cooling, power and computing are usually managed by different teams with different tools. We look at them together, independently of any vendor.

Security

Facility controls

BMS, DCIM and power monitoring reviewed for internet exposure, access and firmware. Changes and new connections monitored.

Performance

Cooling efficiency

Cooling setpoints, airflow and control rules tuned to the real IT load. Sensors checked against a reference.

Performance · Grid

Grid-aware operation

Cooling, power and workload scheduling coordinated with price, carbon and grid signals, so the site can reduce demand during rare peaks without touching critical services.

Vendor-neutral across DCIM and BMS platforms, BACnet and Modbus, and workload schedulers such as Kubernetes and Slurm.

How every engagement runs

Assess, fix, verify, monitor.

  1. 01 · Fixed fee

    Assess

    Inventory, trend data and an interview on site, plus 2 weeks of our own portable sensors for temperature, CO₂, particles and humidity. Then a report where every finding has its impact, cost to fix and priority.

  2. 02 · Fixed fee per scope

    Fix

    Most fixes are access, rules and settings, not new equipment. Physical work goes to licensed partners we specify, manage and check. Hardware is paid by you directly, with no markup.

  3. 03 · Included

    Verify

    About 30 days later we check again against the baseline: access paths closed, energy and cost change in real numbers, air quality improved.

  4. 04 · Annual subscription

    Monitor

    Continuous checks with a short monthly action list. Read-only to start. Permanent sensors where needed, bought by you at cost, plus a fixed install fee.

The assessment report

Every finding tells you what's wrong, what it costs you and what it costs to fix.

Finding and solution

The problem in plain words, the evidence, and what to change.

Impact

Security: risk rating. Performance: cost wasted a year. Air: people and hours affected.

Fix and return

Estimated cost to fix, and payback, risk closed or comfort gained.

Priority

Fix now, quick win, or plan for later. Savings are verified after the fix.

Sample report · findings

Illustrative office building, 12,000 m², plus 3 retail sites

Findings 8

Est. savings €36,900£32,300$40,400 a year

Total fix cost €15,450£13,450$16,750

securityFix now

BMS reachable from the internet with the default admin password. Four former contractor accounts still active.

Solution: Remove internet exposure, move remote access behind a VPN, reset passwords and delete old accounts.

Impact

High risk

Fix

€700, 1 day£600, 1 day$800, 1 day

Return

Risk closed

securityFix now

Refrigeration controllers in 3 stores run firmware that no longer gets security updates.

Solution: Isolate them from the store network now; update or replace them in a planned upgrade.

Impact

High risk, 3 sites

Fix

€2,100£1,800$2,300

Return

Risk closed

securityQuick win

Nobody is told when setpoints, schedules or user accounts change.

Solution: Turn on change logging and send alerts to a named person, day and night.

Impact

Medium risk

Fix

€450£400$500

Return

Changes seen same day

performanceQuick win

Heating and cooling running at the same time on level 2. Night setback overridden since 2023.

Solution: Widen the gap between heating and cooling setpoints and restore the night setback.

Impact

€21,000 a year£18,400 a year$23,000 a year

Fix

€2,400£2,100$2,600

Return

6-week payback

performanceQuick win

Air handlers running 24 hours a day. The schedule was never updated after opening hours changed.

Solution: Rebuild schedules around real occupancy, including holidays.

Impact

€11,100 a year£9,700 a year$12,100 a year

Fix

€900£800$1,000

Return

1-month payback

performanceQuick win

Supply air sensor on AHU-3 reads 2.5 °C low, so the zones it serves are overcooled.

Solution: Replace the sensor and check the others on the same unit.

Impact

€4,800 a year£4,200 a year$5,300 a year

Fix

€400£350$450

Return

1-month payback

airPlan

Meeting rooms above 1,400 ppm CO₂ for a third of occupied hours. Ventilation runs on a fixed timer instead of responding to CO₂ levels.

Solution: Add demand-based ventilation driven by CO₂ sensors in the meeting rooms.

Impact

120 staff

Fix

€7,500£6,500$8,000

Return

Comfort, focus

airQuick win

Air handler filters overdue. Indoor PM2.5 tracks outdoor levels from the busy road.

Solution: Fit higher-grade filters and set a replacement schedule.

Impact

2 floors

Fix

€1,000£900$1,100

Return

Cleaner air

Featured service

Refrigeration Controls Security Check

Refrigeration controllers are often reachable from the internet so contractors can manage them remotely. In October 2026 that access was used to force supermarket freezers into a 50 °C defrost cycle across hundreds of stores. Our fixed-price check shows whether your sites are exposed, and how to close the gaps without losing remote service.

  1. 1Inventory of supervisory controllers and every remote-access path, with model, firmware and end-of-life status
  2. 2Passive check for controller interfaces reachable from the internet
  3. 3Access review: default or shared passwords, former contractors, who can change setpoints and defrost
  4. 4Our own temperature sensors in sample cases for 2 weeks, compared with what the controller reports
  5. 5Risk rating per site, prioritised fixes aligned with national cyber guidance, and a one-page board summary

How we deliver

Pasot leads every engagement and owns the result. Specialist engineers join where the work needs them: controls, refrigeration and OT security. You deal with one firm throughout.

Works with any brand

BACnet, Modbus, KNX and the major refrigeration and BMS platforms. No preferred vendor.

Read-only first

We start by observing. Nothing is changed without your written approval.

Your contractors stay

We work alongside your maintenance and refrigeration contractors, not instead of them.

What we don't do

Sell equipment, guarantee savings percentages, or push replacement of systems that can be fixed.

Not sure where to start?

In 20 minutes we'll tell you which service to start with, and what it would cost.